Aluminium Conductors International
|
|
TTH offers Aluminium Conductors Made in India and Europe
|
| S. No. | Type Code | International Specifications | Nominal Area From | MM2 To | Strands From | To | | 1 | AAC | BS 215, Part 1:1970 | 22.0 | 400.0 | 7 | 37 | | 2 | AAC | BS EN 50182:2001 | 26.9 | 628.3 | 7 | 37 | | 3 | AAAC | BS EN 50182:2001 | 18.8 | 996.2 | 7 | 61 | | 4 | ACSR | BS 215, Part 2:1970 | 25.0 | 400.0 | 7 | 61 | | 5 | AAC | DIN 48 201 Part 5 (1981) | 16.0 | 1000.0 | 7 | 91 | | 6 | AAAC | DIN 48 201 Part 6 (1981) | 16.0 | 1000.0 | 7 | 91 | | 7 | AAC (A1) | IEC 61089 | 10.0 | 1500.0 | 7 | 91 | | 8 | AAAC (A2) | IEC 61089 | 18.4 | 1439.0 | 7 | 91 | | 9 | AAAC (A3) | IEC 61089 | 18.6 | 1301.0 | 7 | 91 | | 10 | ACSR (A1/S1A) | IEC 61089-1991 | 18.7 | 1303.0 | 7 | 91 | | 11 | ACSR (A1/S1B) | IEC 61089-1991 | 18.7 | 1352.0 | 7 | 103 | | 12 | ACSR (A1/S2A) | IEC 61089-1991 | 18.7 | 1352.0 | 7 | 103 | | 13 | ACSR (A1/S2B) | IEC 61089-1991 | 18.7 | 1352.0 | 7 | 103 | | 14 | ACSR (A1/S3A) | IEC 61089-1991 | 18.7 | 1352.0 | 7 | 103 | | 15 | AACSR (A2/S1A) | IEC 61089-1991 | 21.5 | 1394.0 | 7 | 103 | | 16 | AACSR (A2/S1B) | IEC 61089-1991 | 21.5 | 1394.0 | 7 | 103 | | 17 | AACSR (A2/S3A) | IEC 61089-1991 | 21.5 | 1394.0 | 7 | 103 | | 18 | AACSR (A3/S1A) | IEC 61089-1991 | 21.7 | 1407.0 | 7 | 103 | | 19 | AACSR (A3/S1B) | IEC 61089-1991 | 21.7 | 1407.0 | 7 | 103 | | 20 | AACSR (A3/S3A) | IEC 61089-1991 | 21.7 | 1407.0 | 7 | 103 | | 21 | ACSR (A1/A2) | IEC 61089-1991 | 17.0 | 1444.0 | 7 | 91 | | 22 | ACAR (A1/A3) | IEC 61089-1991 | 17.1 | 1447.0 | 7 | 91 | | 23 | AAC (AL1) | EN 50182:2001 | 15.9 | 999.7 | 7 | 91 | | 24 | AAAC (AL2) | EN 50182:2001 | 177.6 | 638.3 | 19 | 61 | | 25 | AAAC (AL3) | EN 50182:2001 | 18.8 | 996.2 | 7 | 61 | | 26 | AAAC (AL3) | EN 50182:2001 | 15.9 | 999.7 | 7 | 91 | | 27 | AAAC (AL4) | EN 50182:2001 | 22.0 | 1595.9 | 7 | 127 | | 28 | AAAC (AL5) | EN 50182:2001 | 239.4 | 996.2 | 37 | 61 | | 29 | AAAC (AL6) | EN 50182:2001 | 46.2 | 865.4 | 7 | 61 | | 30 | AAAC (AL7) | EN 50182:2001 | 46.2 | 865.4 | 7 | 61 | | 31 | ACSR (AL1/ST1A) | EN 50182:2001 | 39.5 | 215.3 | 7 | 61 | | 32 | ACSR (AL1/ST1A) | EN 50182:2001 | 37.7 | 288.3 | 12 | 37 | | 33 | ACSR (AL1/ST6C) | EN 50182:2001 | 116.2 | 1184.5 | 37 | 91 | | 34 | ACSR (AL1/ST1A) | EN 50182:2001 | 17.8 | 1090.9 | 7 | 79 | | 35 | ACSR (AL1/ST1A) | EN 50182:2001 | 36.0 | 1529.7 | 9 | 109 | | 36 | ACSR (AL1/ST1A) | EN 50182:2001 | 62.4 | 315.6 | 7 | 39 | | 37 | ACSR (AL1/ST1A) | EN 50182:2001 | 12.4 | 597.0 | 7 | 61 | | 38 | ACSR (AL1/ST1A) | EN 50182:2001 | 49.5 | 1865.4 | 7 | 187 | | 39 | ACSR (AL1/ST3D) | EN 50182:2001 | 49.5 | 1865.4 | 7 | 187 | | 40 | ACSR (AL1/ST4A) | EN 50182:2001 | 49.5 | 1865.4 | 7 | 187 | | 41 | AACSR (AL4/ST6C) | EN 50182:2001 | 37.7 | 1184.0 | 12 | 91 | | 42 | AACSR (AL3/ST5E) | EN 50182:2001 | 182.4 | 1893.9 | 35 | 187 | | 43 | AL59-SWEDISH | SS 424 0814 | 31.0 | 910.0 | 7 | 61 | | 44 | AL57-SWEDISH | SS 424 0812 | 31.0 | 910.0 | 7 | 61 | | 45 | AAAC-Australian | AS 1531-1991 (6201) | 34.36 | 673.40 | 7 | 61 | | 46 | AAAC-American | ASTM B 399-1997 | 15.5 | 729.2 | 7 | 61 | | 47 | AAAC-American | ASTM B 399-1997 | 13.3 | 886.7 | 7 | 61 | | 48 | ASCR-American | ASTM B 232-B232 M1999 | 12.5 | 1250 | 7 | 79 | | 49 | ASCR-American | ASTM B 232-B232 M1999 | 10.11 | 45.77 | 7 | 95 | | 50 | ACAR-American | ASTM B 524-1978 | 594.0 | 1263.0 | 37 | 81 | | 51 | ACAR-American | ASTM B 524-1978 | 179.9 | 562.0 | 19 | 37 |
Remarks Detailed information about wire size, Kg/Km, Rated Strength KN, DC Resistance etc. will be informed as per requirement and based on specific inquiries.
| AAC | All Aluminium Conductor | | AAAC | All Aluminium Alloy Conductor | | ACSR | Aluminium Conductor Steel Reinforced | | AACSR | Aluminium Conductor Steel Reinforced | | ACAR | Aluminium Conductor Alloy Reinforced | | AL-59 | Alloy Conductor | | AL-57 | Alloy Conductor |
|
| |
|
|